Affichage de 1–16 sur 21 résultats
-
BI04F01KNX ( Din Module 4 Digital Inputs )
Mechanical data
• Dimensions: 4 DIN modules
Supply
• Via EIB/KNX bus cable: 21 ÷ 32V DC
• Max 15 mA
Input – digital mode
• For free potential contacts (dry contacts)
• Max. length of Connecting Cables ≤ 100 m (twisted cable)
Input – analog mode for temperature probe
For NTC temperature probe eelectron code:
• TS01A01ACC (range from -20°C to +100°C)
• TS01B01ACC (range from -50°C to +60°C)
• TS01D01ACC (range from -50°C to +60°C)
• Max. length of Connecting Cable: ≤ 30 m (twisted cable) -
BI08F01KNX (Din Module 8 Digital Inputs)
Mechanical data
• Dimensions: 4 DIN modules
Supply
• Via EIB/KNX bus cable: 21 ÷ 32V DC
• Max 15 mA
Input – digital mode
• For free potential contacts (dry contacts)
• Max. length of Connecting Cables ≤ 100 m (twisted cable)
Input – analog mode for temperature probe
For NTC temperature probe eelectron code:
• TS01A01ACC (range from -20°C to +100°C)
• TS01B01ACC (range from -50°C to +60°C)
• TS01D01ACC (range from -50°C to +60°C)
• Max. length of Connecting Cable: ≤ 30 m (twisted cable) -
BI16F01KNX (Din Module 16 Digital Inputs)
Mechanical data
• Dimensions: 8 DIN modules
Supply
• Via EIB/KNX bus cable: 21 ÷ 32V DC, max 5 mA
• Auxiliary supply: 230V AC
Input – digital mode
• For free potential contacts (dry contacts)
• Max. length of Connecting Cables ≤ 100 m (twisted cable) -
BO04F01KNX (Universal Actuator 4 OUT Plus)
Mechanical data
• Dimensions: 4 DIN modules
Supply
• Via EIB/KNX bus cable: 21 ÷ 32V DC
• Max 10 ÷ 30 mA (ETS parameter)
Output rate
• 16A cos φ 1 – 230V AC
• 8A cos φ 0.6 – 230V AC
• Max current relay output: 16A/16AX (140 µF)
• Max peak current: 165 A / 20 ms
• Incandescent lamps: max 10 A
• Motors e motor reduction units: max 10A
• Fluorescent lamps (max 140 μF) max 3A (700 W)
• Electronic ballast: max 6A
• LED’s lamps drivers: always check that the maximum
peak current drawn by led power supply is lower
than maximum peak current allowed for the relay -
BO08F01KNX ( DIN MODULE 8 OUT PLUS)
Mechanical data
• Dimensions: 4 DIN modules
Supply
• Via EIB/KNX bus cable: 21 ÷ 32V DC
Max 10 ÷ 30 mA (ETS parameter)
Output rate
• 16A cos φ 1 – 230V AC
•8 A cos φ 0.6 – 230V AC
•Max current relay output: 16A/16AX (140 µF)
•Max peak current: 165 A / 20 ms
•Incandescent lamps: max 10 A
•Motors e motor reduction units: max 10 A
•Fluorescent lamps (max 140 μF) max 3 A (700 W)
•Electronic ballast: max 6A
LED’s lamps drivers: always check that the maximum
peak current drawn by led power supply is lower
than maximum peak current allowed for the relay -
HC3-KNX
Control unit for KNX-based home and building automation installations, featuring
a 7” TFT capacitive touch screen, integrated web server, and video door phone
function. GLASS (full glass front) and CLASSIC (interchangeable front frames)
models available.
Function highlights:
o Control and monitoring of KNX devices
o Simple, user-friendly navigation through floorplans and zones
o Up to 512 configurable pages, with up to 8 control functions per
page (more than 4000 functions)
o Customizable background images
o User-editable scenes
o Weekly time schedules
o Alarm monitoring with event log
o Presence simulation with day and night schedules
o Event notifications by e-mail and GSM (*)
o Logic functions (logic gates, comparators, timers, etc.)
o Four independent thermostats
o Touch gestures: 4 directional gestures + multitouch gesture
o Video door phone function, with full duplex audio and echo cancellation () o IP camera monitoring ()
Remote control from smartphones, tablets, and PCs
Integrated stereo loudspeakers and digital microphone
Four multi-function inputs, individually configurable as binary or temperature probe inputs
Real-time clock (RTC) with backup battery
Integrated KNX bus coupling unit
Very low power consumption -
HC3L-KNX
Control unit for KNX-based home and building automation installations, featuring a
10,1” TFT capacitive touch screen with IPS technology, integrated web server, and
video door phone function. GLASS (full glass front) and CLASSIC (interchangeable
front frames) models available.
Function highlights:
o Control and monitoring of KNX devices
o Simple, user-friendly navigation through floorplans and zones
o Up to 512 configurable pages, with up to 8 control functions per page
(more than 4000 functions)
o Customizable background images
o User-editable scenes
o Weekly time schedules
o Alarm monitoring with event log
o Presence simulation with day and night schedules
o Event notifications by e-mail and GSM (*)
o Logic functions (logic gates, comparators, timers, etc.)
o Four independent thermostats
o Touch gestures: 4 directional gestures + multitouch gesture
o Video door phone function, with full duplex audio and echo cancellation () o IP camera monitoring ()
Remote control from smartphones, tablets, and PCs
Integrated stereo loudspeakers and digital microphone
Four multi-function inputs, individually configurable as binary or temperature probe inputs
Real-time clock (RTC) with backup battery
Integrated KNX bus coupling unit
Very low power consumption -
IO04F01KNX (Universal Actuator 4 IN / 4 OUT Plus)
Mechanical data
• Dimensions: 4 DIN modules
Supply
• Via EIB/KNX bus cable: 21 ÷ 32V DC
• Max 10 ÷ 30 mA (ETS parameter)
Input – digital mode
• For free potential contacts (dry contacts)
• Max. length of Connecting Cables ≤ 30 m (twisted cable)
Input – analog mode for temperature probe
• For NTC temperature probe eelectron code:
• TS01A01ACC (range from -20°C to +100°C)
• TS01B01ACC (range from -50°C to +60°C)
• TS01D01ACC (range from -40°C to 125°C)
• Max. length of Connecting Cable: ≤ 20 m (twisted cable)
Output rate
• 16A cos φ 1 – 230V AC
• 8 A cos φ 0.6 – 230V AC
• Max current relay output: 16A/16AX (140 µF)
• Max peak current: 165 A / 20 ms
• Incandescent lamps: max 10 A
• Motors e motor reduction units: max 10 A
• Fluorescent lamps (max 140 μF) max 3 A (700 W)
• Electronic ballast: max 6A
• LED’s lamps drivers: always check that the maximum
peak current drawn by led power supply is lower than maximum peak current allowed for the relay -
IO08F01KNX (Universal Actuator 8 IN / 8 OUT Plus)
Mechanical data
• Dimensions: 4 DIN modules
Supply
• Via EIB/KNX bus cable: 21 ÷ 32V DC
• Max 10 ÷ 30 mA (ETS parameter)
Input – digital mode
• For free potential contacts (dry contacts)
• Max. length of Connecting Cables ≤ 30 m (twisted cable)
Input – analog mode for temperature probe
• For NTC temperature probe eelectron code:
• TS01A01ACC (range from -20°C to +100°C)
• TS01B01ACC (range from -50°C to +60°C)
• TS01D01ACC (range from -40°C to 125°C)
• Max. length of Connecting Cable: ≤ 20 m (twisted cable)
Output rate • 16A cos φ 1 – 230V AC
• 8 A cos φ 0.6 – 230V AC
• Max current relay output: 16A/16AX (140 µF)
• Max peak current: 165 A / 20 ms
• Incandescent lamps: max 10 A
• Motors e motor reduction units: max 10 A
• Fluorescent lamps (max 140 μF) max 3 A (700 W)
• Electronic ballast: max 6A
• LED’s lamps drivers: always check that the maximum
peak current drawn by led power supply is lower than maximum peak current allowed for the relay -
IO12F01KNX (Universal Actuator 12 IN / 12 OUT Plus)
د.ت 2.100.000,000Mechanical data
• Dimensions: 6 DIN modules
Supply
• Via EIB/KNX bus cable: 21 ÷ 32V DC
• Max 10 ÷ 30 mA (ETS parameter)
Input – digital
mode
• For free potential contacts (dry contacts)
• Max. length of Connecting Cables ≤ 30 m (twisted cable)
Input – analog
mode for
temperature probe
• For NTC temperature probe eelectron code:
• TS01A01ACC (range from -20°C to +100°C)
• TS01B01ACC (range from -50°C to +60°C)
• TS01D01ACC (range from -40°C to 125°C)
• Max. length of Connecting Cable: ≤ 20 m (twisted cable)
Output rate
• 16A cos φ 1 – 230V AC
• 8 A cos φ 0.6 – 230V AC
• Max current relay output: 16A/16AX (140 µF)
• Max peak current: 165 A / 20 ms
• Incandescent lamps: max 10 A
• Motors e motor reduction units: max 10 A
• Fluorescent lamps (max 140 μF) max 3 A (700 W)
• Electronic ballast: max 6A
• LED’s lamps drivers: always check that the maximum
peak current drawn by led power supply is lower
than maximum peak current allowed for the relay -
IO16F01KNX ( Universal Actuator 16 IN / 16 OUT Plus)
Mechanical data
• Dimensions: 8 DIN modules
Supply
• Via EIB/KNX bus cable: 21 ÷ 32V DC
• Max 10 ÷ 30 mA (ETS parameter)
Input – digital
mode
• For free potential contacts (dry contacts)
• Max. length of Connecting Cables ≤ 30 m (twisted cable)
Input – analog
mode for
temperature probe
• For NTC temperature probe eelectron code:
• TS01A01ACC (range from -20°C to +100°C)
• TS01B01ACC (range from -50°C to +60°C)
• TS01D01ACC (range from -40°C to 125°C)
• Max. length of Connecting Cable: ≤ 20 m (twisted cable)
Output rate
• 16A cos φ 1 – 230V AC
• 8 A cos φ 0.6 – 230V AC
• Max current relay output: 16A/16AX (140 µF)
• Max peak current: 165 A / 20 ms
• Incandescent lamps: max 10 A
• Motors e motor reduction units: max 10 A
• Fluorescent lamps (max 140 μF) max 3 A (700 W)
• Electronic ballast: max 6A
• LED’s lamps drivers: always check that the maximum
peak current drawn by led power supply is lower
than maximum peak current allowed for the relay -
Thermostat domotique FAN 2M diamant blanc
Thermostat Eikon Tactil pour domotique à écran tactile pour le contrôle de la température ambiante (chauffage et climatisation), contrôle FAN-COIL 3 vitesses et proportionnel, dispositif de contrôle de température classe I (contribution 1%) en ON/OFF mode, classe IV (contribution 2%) en mode PID, interfaçable avec l’actionneur à sorties analogiques proportionnelles 01466.1 pour créer un Thermostat d’ambiance modulant classe V (contribution 3%), 1 entrée pour sonde de température électronique 20432, 19432 ou 14432 ou sonde de température filaire 02965.1, 1 entrée numérique programmable, rétroéclairage LED RGB, blanc diamant – 2 modules
-
VERSO+IP 2
4,3” capacitive touch panel for visualisation and control of KNX installations.
IP connectivity allows for remote control from smartphones and tablets. Available
in white or black GLASS finish, can be installed in portrait or landscape mode.
Function highlights:
o Up to 96 control functions, organized in 12 configurable pages
o User editable favorites page
o Configurable background images
o Weekly time schedules (up to 96 channels, 4 programs / channel)
o Alarm monitoring (up to 96 alarms) with event log
o Touch gestures: up to 5 quick actions (4 directions + multitouch), even
with the display off (power saving mode)
o Internal scene controller
o Two independent thermostats
Remote control from smartphones and tablets via mobile apps
Four multi-function inputs, individually configurable as binary or temperature probe
inputs
Built-in temperature sensor
Real-time clock (RTC) with backup battery
Integrated KNX bus coupling unit
Ultra-low power consumption -
Vivaldi Giove AL5B
DIN rail power supply (5,5 modules DIN)
Input 100-240 Vac 50Hz 1,2A
Output 24 Vdc, 4,16A, 100W
Colour black.
Dimensions: 99x93x56 mm (WxHxD)
Weight 0,29 Kg. -
Vivaldi Giove AL6B
DIN rail power supply (6 modules)
Input 100-240 Vac 50Hz 1,8A
Output 24 Vdc 6,25A, 150W
Black colour
Dimensions 103x58x90 mm (WxHxD)
Weight 0,35 Kg